X-ray response of CdZnTe detectors grown by the vertical Bridgman technique: Energy, temperature and high flux effects

2016

Abstract Nowadays, CdZnTe (CZT) is one of the key materials for the development of room temperature X-ray and gamma ray detectors and great efforts have been made on both the device and the crystal growth technologies. In this work, we present the results of spectroscopic investigations on new boron oxide encapsulated vertical Bridgman (B-VB) grown CZT detectors, recently developed at IMEM-CNR Parma, Italy. Several detectors, with the same electrode layout (gold electroless contacts) and different thicknesses (1 and 2.5 mm), were realized: the cathode is a planar electrode covering the detector surface (4.1×4.1 mm2), while the anode is a central electrode (2×2 mm2) surrounded by a guard-rin…

0301 basic medicine030103 biophysicsNuclear and High Energy PhysicsHigh fluxDigital pulse shape analysi01 natural sciencesBoron oxide encapsulated vertical Bridgmanlaw.invention03 medical and health scienceslaw0103 physical sciencesPolarization (electrochemistry)InstrumentationPhysicsX-ray and gamma ray detectors010308 nuclear & particles physicsbusiness.industryCdZnTe detectorsCdZnTe detectorEnergy-resolved photon counting detectorSettore FIS/01 - Fisica SperimentaleDetectorGamma raySettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)CathodePhoton countingAnodeFull width at half maximumElectrodeEnergy-resolved photon counting detectorsOptoelectronicsDigital pulse shape analysisbusinessNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Digital fast pulse shape and height analysis on cadmium-zinc-telluride arrays for high-flux energy-resolved X-ray imaging.

2017

Cadmium-zinc-telluride (CZT) arrays with photon-counting and energy-resolving capabilities are widely proposed for next-generation X-ray imaging systems. This work presents the performance of a 2â...mm-thick CZT pixel detector, with pixel pitches of 500 and 250â...μm, dc coupled to a fast and low-noise ASIC (PIXIE ASIC), characterized only by the preamplifier stage. A custom 16-channel digital readout electronics was used, able to digitize and process continuously the signals from each output ASIC channel. The digital system performs on-line fast pulse shape and height analysis, with a low dead-time and reasonable energy resolution at both low and high fluxes. The spectroscopic response …

0301 basic medicine030103 biophysicsNuclear and High Energy PhysicsMaterials sciencePreamplifierInstrumentationenergy-resolved photon counting detectordigital pulse shape analysienergy-resolved photon counting detectors01 natural sciencesCharge sharing03 medical and health scienceschemistry.chemical_compoundOpticshigh flux0103 physical sciencesInstrumentationX-ray and ?-ray detectorsNuclear and High Energy Physiccharge sharingRadiationdigital pulse shape analysisPixel010308 nuclear & particles physicsbusiness.industryCdZnTe detectorsCdZnTe detectorSettore FIS/01 - Fisica SperimentaleDetectorX-ray and γ-ray detectorBiasingSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Cadmium zinc telluridechemistryDirect couplingbusinessJournal of synchrotron radiation
researchProduct